Technology

Energy Management

The EMS developed by our solution partner EnerjiOne provides end-to-end monitoring, control and optimization for grid-supported BESS projects.

  • Integrated Site Compatibility

    Integration with site panels and SCADA systems.

  • Cyber Secure and Resilient

    Cybersecurity measures and industrial durability.

  • Efficient and Scalable

    Performance is monitored and reported, capacity grows with the need.

EMS Panel
EnerjiOne EMS overview screen
Illustrative display

Features

  • Real-Time Monitoring
  • Alarm Management
  • Asset-Based Control
  • Reporting
  • SCADA Integration
  • Site Panel Integration
  • Live Telemetry
  • High Reliability

Power Conversion

The power conversion system (PCS) is the bridge between the battery and the grid and connects to the grid through a transformer. It is chosen and set to run in grid following or grid forming mode. A PCS with reactive power control holds the voltage in its band and the power factor at its target.

  • Bidirectional Conversion

    Converts alternating current to direct current while the battery charges, and direct current to alternating current while it discharges.

  • EMS Command

    The EMS decides when and at what power the battery runs; the power conversion system carries out that decision.

  • Safe Operation

    Current, voltage and temperature are monitored during conversion; the system runs within safe limits.

  1. GridAlternating currentMeter dataAC
  2. TransformerVoltage conversionAC
  3. Power Conversion (PCS)ATESSCommand and statusDC
  4. BatteryDirect currentBMS data
EnerjiOne EMSCollects the data, decides and sends the command to the power conversion system.

Power Conversion

  • DC Side: Battery Connection
  • AC Side: Grid via Transformer
  • Efficiency
  • Grid Connection Compliance

Cooling and Safety

  • Liquid Cooling

    The liquid runs from the cooling unit to the racks, passes from module to module and returns; the cell temperature is kept even.

  • Fire Detection and Suppression

    The detection line notices a fire early, the suppression circuit starts and sprays dry chemical powder from the ceiling.

  • DC Side and Protection

    Busbars and the protection panel carry the direct current of the batteries to the power conversion system.

  • Battery Management (BMS)

    State of charge, temperature and health are monitored at cell and module level.

Our Component Selection Criteria

  • Battery Cell and Module

    Chemistry (LFP), cycle life, temperature range, international tests and certificates.

  • Battery Management System (BMS)

    Cell level monitoring, balancing, protection functions.

  • Power Converter (PCS)

    Efficiency, grid connection compliance, communication protocols.

  • Cabinet and Cooling

    Protection class, thermal management, fire detection and suppression.

  • Energy Management System (EMS)

    Control strategies, remote monitoring, reporting.