Services

Our Service Steps

The Lİ3 team reviewing power analyser measurements and invoice data at the meeting tableThe Lİ3 team reviewing the system design diagram on screen in the site project officeA white Lİ3 energy storage container lifted into place by craneThe Lİ3 team running tests at the BESS test and commissioning panel on siteThe Lİ3 team monitoring battery and inverter data on the video wall of the control room
  1. The Lİ3 team reviewing power analyser measurements and invoice data at the meeting table

    Feasibility Study and Measurement

    We study the consumption and invoice data and measure on site when needed.

    • A review of the invoice and meter data
    • Power quality and load measurement on site when needed
    • The main consumers of the site and its operating scenario

    Handed overFeasibility report: load profile, proposed power and energy range

  2. The Lİ3 team reviewing the system design diagram on screen in the site project office

    System Engineering

    We size the capacity and prepare the single line diagram and the protection coordination.

    • Power and energy sized on the measured load profile
    • Single line diagram and protection coordination
    • A quote with its assumptions in writing

    Handed overTechnical design file and quote

  3. A white Lİ3 energy storage container lifted into place by crane

    Supply and Integration

    We select the components and integrate the cabinet and the control system.

    • Battery and power converter chosen for what the project needs
    • Integration of the cabinet and the control system
    • Managed as one system with EnerjiOne EMS

    Handed overFactory acceptance test (FAT) records

  4. The Lİ3 team running tests at the BESS test and commissioning panel on site

    Testing and Commissioning

    We install on site, complete the grid connection and run the performance test.

    • Installation on site
    • Completion of the grid connection
    • Measured performance and a signed acceptance record

    Handed overCommissioning and performance test report

  5. The Lİ3 team monitoring battery and inverter data on the video wall of the control room

    Operation and Service

    We monitor remotely, carry out periodic maintenance and respond to faults.

    • Remote monitoring and reporting with EnerjiOne EMS
    • Periodic maintenance
    • Fault reporting and response

    Handed overService level agreement (SLA) and periodic performance report

The Project Life Cycle

One team runs a project from start to finish. Each step ends with a concrete output in your hands.

  1. Feasibility Study and Measurement

    Feasibility report

  2. System Engineering

    Technical design file and quote

  3. Supply and Integration

    Factory acceptance test (FAT) records

  4. Testing and Commissioning

    Commissioning and performance test report

  5. Operation and Service

    SLA and periodic performance report